Skip to the content

M-VET All Terrain

The M-VET All Terrain is a robust portable solution including the new-generation Class 4 Therapeutic Laser device, heavy duty hard case and battery kit. The system has a large HD touchscreen with user friendly software and over 250 protocols. It comes with a range of interchangeable heads to enable treatment of a wide variety of pathologies and can easily be transported due to it's ergonomic design, large capacity battery and specifically designed carry-case. Ideal for physiotherapists or those who provide mobile laser treatments.

The patented MLS® system delivers pulsed and continuous laser emissions synchronised for the optimal therapeutic effect with wavelengths of 808nm and 905nm. The advanced MLS® laser technology allows true pulsed emissions to achieve peak power of 270 watts, without the risk of thermal damage.

Features:

  • New optical fibre technology enables higher peak powers(270W)
  • Thermal safety is ensured using world renowned pulse technology
  • 10.1” touch screen and state-of-the-art software provides unique user experience.
  • Intelligent treatment guidance for a huge range of conditions
  • Four electronically connected interchangeable heads
    • Standard – with universal head for point treatments
    • Large – treat large muscle groups in minutes
    • Acupuncture – for those patients who can’t tolerate needles
    • Intra-oral – get into the difficult to reach areas
  • Heavy duty case
  • Battery kit - charger, 2x lithium-ion batteries, connection cable

MLS® Laser is a Class 4 laser – the high power means shorter treatment times and quicker treatment benefits for your patients. MLS® offers 25W (Vet Blue) or 270W (M-Vet) peak power options. Both of these provide significant and similar clinical benefits. The 270W unit has shorter treatment times and requires fewer treatment sessions overall to see a similar clinical result.

The key differences between MLS® laser and other class 4 lasers are:

  • MLS®’s unique nanopulse technology which means MLS® is a NON-THERMAL laser and does not generate any dangerous heat build-up within the tissues – the handset can be held still and is therefore ideal for focused treatment over trigger points, joints, wound edges, disc spaces.  
  • MLS® delivers both 905nm and 808nm wavelengths in a simultaneous and synchronised system, reducing treatment times and increasing treatment efficacy. No need to change settings or handpieces for different wavelength delivery
  • Wounds– post-surgical, traumatic, non-healing
  • Degenerative joint disease
  • Acute and chronic tendon and ligament injuries
  • Muscle strains and trigger points
  • Neurogenic pain
  • Skin conditions

Technical features

  • Laser source with impulse in MLS® mode up to 3.6W
  • Peak power outside handpiece: 270W
  • MLS® modulation in CPW and FPW (synchronised emission of Continuous Pulsed Wave and Frequenced Pulsed Wave)
  • MLS® pulse modulation frequency from 1 to 2000 Hz in 1Hz steps
  • Power level from 1% to 100%
  • Lens with target area highlighted by high efficiency red light LEDs
  • Automatic recognition of the lens
  • 10.1" high brightness LCD touchscreen display
  • Intelligent back-up system
  • Pre-set programs for pets, horses, reptiles, birds and exotic mammals
  • Programs section for laser puncture
  • Programs section for diseases of the oral cavity
  • Viewing treatment images
  • Possibility of customising each treatment parameter
  • Reserved area to save personal protocols
  • Treatment time from 1" to 29'59" in steps of 1"
  • Automatic calculation of the energy emitted according to the parameters set
  • Treatment log
  • Usage statistics

Alarms and safety equipment

  • Laser emission warning light
  • Interlock
  • Acoustic signal adjustable by the operator
  • Date and time
  • Password to operate the device
  • Language option
  • Ready to be connected to the remote Laser emission signaling device

Accessories provided

  • Heavy duty case
  • Battery kit: consisting of charger, 2x lithium-ion battery, mains connection cable
  • 4 lenses: Ø 4 mm, Ø 8 mm, Ø 2 cm, Ø 5 cm
  • N° 2 Laser Safety Goggles
  • Unit carrying case
  • Shoulder strap for portable use
  • Lens case attachable to the shoulder strap

Dimensions and weight

  • 35 x 30 x 15 cm; 4 kg (max)

Power supply

  • Lithium-ion battery
  • 100 - 240 V AC 50/60 Hz 51-68 VA external power supply unit

Optional accessories

  • Trolley with storage compartment:
    • 4 swivel wheels and self-locking system
    • 52 x 50 x 95 cm (L x P x H), 19 Kg

Each year the ASAcampus (an association between ASAlaser and The University of Florence) publish 'Energy for Health', a scientific magazine focusing on the results of research and clinical studies carried out by internationally renowned researchers, doctors and specialists both in Italy and abroad.

Energy for Health 2020
Energy for Health 2019
Energy for Health 2018
Energy for Health 2017
Energy for Health 2016
Energy for Health 2015
Energy for Health 2014

Get in touch about this item

Our expert team will happily help with any questions you may have.

Please select department
Please select profession
The 'First name' field is required
The 'Last name' field is required
Please enter a valid Email address

Get In Touch

Chat with one of our friendly team members today.